Go To

EB-232

Discontinued
Configuration Backup and Restoration Tool for Managed Switches
Automatically restore switch configuration files
Quickly compare configuration data on switch and EB-232
Operation through an intuitive GUI
Downloads
Inquiry

The EB-232 dongle provides fast and effortless system backup and restoration on EtherWAN managed switches. In addition to saving and loading switch configuration files directly, the EB-232 can transfer configurations to and from a TFTP server. An automatic restore function can be activated, allowing the configuration saved on a connected EB-232 to be automatically loaded onto the switch when the switch is rebooted or power cycled. This greatly cuts down on system downtime in the event of a switch failure, because a failed switch can be quickly replaced with a new one running the same configuration.

The configuration on a switch can be quickly compared with the data stored on the EB-232, to ascertain if the configurations differ or are identical. This allows an administrator to quickly assess if a switch is running a specific configuration.

EtherWAN — "When Connectivity is Crucial."

 

  • » Automatically restore switch configuration files
  • » Quickly compare configuration data on switch and EB-232
  • » Operation through an intuitive GUI

 

Storage Capacity

  • • 192 KB

Power

  • • 3.3 VDC (through the RS-232 port's RI signal

Interface

LED Indicators

  • • Power LED (Green)
  • • Alarm LED (Green/Amber)

 


Mechanical

Housing

  • • PVC molding

Weight
  • • 64g

 


Environment

Operating Temperature

  • • -40 to 75°C (-40 to 167°F)

Storage Temperature
  • • -40 to 85°C (-49 to 185°F)

Ambient Relative Humidity
  • • 5% to 95% (non-condensing)

 


Regulatory Approvals

ISO

  • • Manufactured in an ISO 9001 facility

EMI
  • FCC Part 15B, Class A
  • VCCI Class A
  • EN 61000-6-4
  • EN 61000-3-2
  • EN 61000-3-3

EMS
  • EN 61000-6-2
    • • EN 61000-4-2 (ESD Standards)
    • • EN 61000-4-3 (Radiated RFI Standards)
    • • EN 61000-4-4 (Burst Standards)
    • • EN 61000-4-5 (Surge Standards)
    • • EN 61000-4-6 (Induced RFI Standards)
    • • EN 61000-4-8 (Magnetic Field Standards)

Environmental Test Compliance
  • IEC 60068-2-6 Fc (Vibration Resistance)
  • FED STD 101C Method 5007.1 (Free fall w/ package)

 

Model

EB-232Configuration Backup and Restoration Tool for Managed Switches

*The following series of managed switches support configuration backup through EB-232
  EX71000, EX73000, EX78000, EX73900, EX77900, EX78900